Dovehouse St

Location

Chelsea

Services

Manufacture, Installation

Value

£660K

Client

ESG

The Dovehouse St Project is a retirement home that is situated in Chelsea.

The Lower Ground Floor to level 5 are comprised of apartments.

Also on the Lower Ground Floor there are a swimming pool, sauna, cinema, restaurant, gym, showers and changing rooms.

The basement houses most of the ventilation and mechanical equipment, such as air handling units, pumps and fans, also situated in the basement are the residents store, wine room and dog grooming parlour which are served from air handling units on the mezz deck. The wine store is also served by a 4 pipe fan coil unit. Due to access issues with motorised dampers the ductwork that was running through the wine room and corridor has had to be changed to fire rated ductwork which is being installed by Fire Protection.

The IDSL scope of works is to install all of the GSS ductwork and fire rated ductwork along with the free issue fan coil units, plenum boxes and grilles on the Dovehouse St project. Fire Protection have been appointed by IDSL to supply and install the fire rated ductwork and insulation to the fire rated ductwork once the installation was complete.

There are dedicated air handling units and extract fans that serve the swimming pool and sauna. The ductwork for these areas has been treated so that it can be installed in this environment and is resistant to the pool chemicals.

Dedicated supply and extract fans serve the energy centre where the pumps and CHP are situated.

The apartments are served by fan coil units that are connected to the grilles that are being installed by others.

The amenity areas are served by a combination of a ducted supply and extract system along with fan coil units that are to be installed within these areas.

A smoke extract system is being installed and the fans are going to be situated on the roof and serve a purpose formed smoke shaft that runs to the basement.

114746_Daikin_D1_Plus_Logo_Main_RGB Achilles considerate-constructors-scheme-logo Construction Line Gold Member ISO-9001-logo ISO-14001-logo ISO-45001-logo MITSUBISHI-ELECTRIC-BUSINESS-SOLUTIONS-PARTNER MITSUBISHI-HEAVY-INDUSTRIES cyberessentials_certification mark_colour LPCB Logo - White CHAS Elite BAB Logo RoSPA 2023 FIRAS Logo